Related Experiment Video
Updated: Jul 15, 2025

Atomic Layer Deposition of Vanadium Dioxide and a Temperature-dependent Optical Model
Published on: May 23, 2018
Extractive Spectrophotometric Determination and Theoretical Investigations of Two New Vanadium(V) Complexes
Kiril B Gavazov1, Petya V Racheva1, Antoaneta D Saravanska1
1Department of Chemical Sciences, Faculty of Pharmacy, Medical University of Plovdiv, 120 Buxton Bros Str., 4004 Plovdiv, Bulgaria.
None:
Two new vanadium (V) complexes involving 6-hexyl-4-(2-thiazolylazo)resorcinol (HTAR) and tetrazolium cation were studied. The following commercially available tetrazolium salts were used as the cation source: tetrazolium red (2,3,5-triphenyltetrazol-2-ium;chloride, TTC) and neotetrazolium chloride (2-[4-[4-(3,5-diphenyltetrazol-2-ium-2-yl)phenyl]phenyl]-3,5-diphenyltetrazol-2-ium;dichloride, NTC). The cations (abbreviated as TT+ and NTC+) impart high hydrophobicity to the ternary complexes, allowing vanadium to be easily extracted and preconcentrated in one step. The complexes have different stoichiometry. The V(V)-HTAR-TTC complex dimerizes in the organic phase (chloroform) and can be represented by the formula [(TT+)[VO2(HTAR)]]2. The other complex is monomeric (NTC+)[VO2(HTAR)]. The cation has a +1 charge because one of the two chloride ions remains undissociated: NTC+ = (NT2+Cl-)+. The ground-state equilibrium geometries of the constituent cations and final complexes were optimized at the B3LYP and HF levels of theory. The dimer [(TT+)[VO2(HTAR)]]2 is more suitable for practical applications due to its better extraction characteristics and wider pH interval of formation and extraction. It was used for cheap and reliable extraction-spectrophotometric determination of V(V) traces in real samples. The absorption maximum, molar absorptivity coefficient, limit of detection, and linear working range were 549 nm, 5.2 × 104 L mol-1 cm-1, 4.6 ng mL-1, and 0.015-2.0 μg mL-1, respectively.
Related Concept Videos
Valence Bond Theory
Complexometric Titration: Overview
Complexometric Titration: Ligands
Extraction: Advanced Methods
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Complexometric EDTA Titration Curves