Background:
Various designs of mini-implants assisted rapid palatal expander (MARPE) appliances can impact treatment effectiveness through their biomechanical effects. The purpose of the study was to study the stress distribution and displacement with four different designs of the MARPE appliance on the craniofacial complex.
Methods:
A 3D finite element model of the craniofacial complex was created from CBCT DICOM data, comprising four distinct groups. Each group consisted of one 4-hole expansion screw positioned between the second premolar and first molar in all models. Group 1 used four single-cortical mini-implants (1.5×8mm) engaging only the palatal cortex. Group 2 employed four mini-implants (1.5×11mm) engaging both the palatal and nasal cortices. Group 3 had monocortical implants on the palatal slopes, while Group 4 was similar to group 3 with implants in the acrylic wings. Comparisons between groups were made for anchorage (groups 1 and 2), mini-implant position (groups 1 and 3) and surface effect (groups 3 and 4). Von Mises stresses and displacements at various skeletal and dental points were evaluated using ANSYS software.
Results:
The highest stresses were observed in the maxillary, pterygoid and zygomatic bones, as well as in the mid- palatal suture in all four groups. Downward and forward rotation of the craniofacial complex was noted. Group 2 showed greater skeletal expansion than group 1. Among groups 1 and 3, group 3 showed a better stress distribution. Group 4 showed less dentoalveolar rotation than group 3.
Conclusions:
The MARPE appliances had an impact on the craniofacial complex with stresses on the mid-palatal suture, maxillary bone, pterygoid bones and anterior teeth. Clockwise rotation of the maxilla, zygomatic bones and dentition was noted, while the pterygoid bones and pterygoid suture were displaced backwards. MARPE with bicortical anchorage produces better skeletal expansion. Placing implants on the palatal slopes with acrylic wings results in better skeletal expansion with less clockwise rotation of the dentition.
Related Concept Videos
Three-Dimensional Analysis of Strain
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Plastic Deformations of Members with a Single Plane of Symmetry