Related Experiment Video
Updated: Jul 13, 2025

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Lessons Learned From the First-In-Human Compassionate Use of Connect-EA™ in Ten Patients With Esophageal Atresia
William G Lee1, Lauren L Evans1, Caressa S Chen1
1Department of Pediatric Surgery, University of California San Francisco, 550 16th Street Box 0570, San Francisco, CA 94143, USA.
Introduction:
Delayed primary repair of esophageal atresia in patients with high-risk physiologic and anatomic comorbidities remains a daunting challenge with an increased risk for peri-operative morbidity and mortality via conventional repair. The Connect-EA device facilitates the endoscopic creation of a secure esophageal anastomosis. This follow-up study reports our long-term outcomes with the novel esophageal magnetic compression anastomosis (EMCA) Connect-EA device for EA repair, as well as lessons learned from the ten first-in-human cases. We propose an algorithm to maximize the advantages of the device for EA repair.
Methods:
Under compassionate use approval, from June 2019 to December 2022, ten patients with prohibitive surgical or medical risk factors underwent attempted EMCA with this device. All patients underwent prior gastrostomy, tracheoesophageal fistula ligation (if necessary), and demonstrated pouch apposition prior to EMCA.
Results:
Successful device deployment and EMCA formation were achieved in nine patients (90%). Mean time to anastomosis formation was 8 days (range 5-14) and the device was retrieved endoscopically in five (56%) cases. At median follow-up of 22 months (range 4-45), seven patients (78%) are tolerating oral nutrition. Balloon dilations (median 4, range 1-11) were performed either prophylactically for radiographic asymptomatic anastomotic narrowing (n = 7, 78%) or to treat clinically-significant anastomotic narrowing (n = 2, 22%) with no ongoing dilations at 3-month follow up post-repair.
Conclusion:
EMCA with the Connect-EA device is a safe and feasible minimally-invasive alterative for EA repair in high-risk surgical patients. Promising post-operative outcomes warrant further Phase I investigation.
Level Of Evidence:
IV, Case series of novel operative technique without comparison group.
More Related Videos
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Esophageal Varices-I: Introduction
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...