Related Experiment Video
Updated: Jul 13, 2025

Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
Published on: April 14, 2014
Visual performance and photic disturbances with diffractive and nondiffractive EDOF intraocular lenses using
Marcelo Caram Fernandes1, Carlos Yuji Nunomura, André Messias
1From the Department of Ophthalmology, Otorhinolaryngology, and Head and Neck Surgery, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
Purpose:
To compare visual performance and photic visual disturbances of patients implanted with 2 different extended depth-of-focus (EDOF) intraocular lenses (IOLs) using mini-monovision.
Setting:
Ambulatory surgical center at the University of São Paulo in Ribeirão Preto, Brazil.
Design:
Prospective, examiner-masked, randomized clinical trial.
Methods:
Patients were assigned to either a bilateral Symfony (SYM) or Vivity (VIV) IOL group, with 1 eye targeted for myopia (-0.75 diopter [D]). Defocus curve, contrast sensitivity (Pelli-Robson), Patient-Reported Spectacle Independence Questionnaire, and Quality of Vision questionnaire were recorded at 3 months postoperatively.
Results:
A total of 126 patients finished the follow-up: group SYM: n = 60 and group VIV: n = 66. Regarding near visual acuity, 80% of patients in the SYM group and 84% of patients in the VIV group achieved J2 or better on the near-planned eye ( P = .3840). No significant differences were found between groups for distance visual acuity, defocus profiles, PRISC, contrast sensitivity, or reading speed ( P > .05). Notably, significant between-group differences were observed for bothersome visual disturbances ( P = .0235), with 45% of patients in the SYM group with a score of 0 for bothersome disturbances compared with 66% in the VIV group.
Conclusions:
Mini-monovision using these EDOF IOLs was well-tolerated in the patient cohort. No significant differences were found for visual performance tests between the VIV and SYM groups. However, the data suggest that Vivity IOL is associated with a lower probability of bothersome visual disturbances compared with Symfony IOL.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...