Background:
Most randomized studies testing the effectiveness of IVBT were limited to vessels less than 4 mm diameter. In fact, it is now common to treat vessels larger than 4 mm. Accordingly, the authors instituted a prescription dose increase to 34 Gy at 2 mm from source center for vessels greater than 4.0 mm. The increase in prescription dose to 34 Gy at 2 mm from center is substantial, being 50% higher than the conventional maximum of 23 Gy.
Aim:
To take a close look at group of patients treated to 34 Gy, and for whom follow-up angiograms are available.
Methods:
Ten patients treated for ISR with a prescription dose of 34 Gy and for whom follow-up angiograms were available were studied. Beta-radiation brachytherapy was performed with a Novoste Beta-Cath System using a strontium-90 (beta) source (Best Vascular, Springfield, VA). Source lengths of 40 or 60 mm were used. A dose of 34 Gy was prescribed at 2 mm from the source center.
Results:
Patients were re-catheterized from 2 to 21 months (median: 16 months) following IVBT, all for symptoms suggested of restenosis. All patients had some degree of ISR of the target vessel, but no IVBT-treated vascular segment showed angiographic signs of degeneration, dissection or aneurysm.
Conclusion:
The authors' clinical impression, along with detailed review of the 10 cases, suggest that using a 34 Gy prescription dose at 2 mm from source center does not result in increased toxicity.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...