Related Experiment Video
Updated: Jul 12, 2025

Author Spotlight: Assessing the Feasibility of Using Amplitude-Integrated EEG During Neonatal Transport
Published on: June 21, 2024
Evaluation of a device to detect neonatal hypothermia in a clinical setting in Ghana
Lauren McAbee1, Paddington T Mundagowa1, Babbel Agbinko-Djobalar2,3
1Department of Epidemiology and Biostatistics, University of South Carolina, Arnold School of Public Health, Columbia, South Carolina, United States of America.
Abstract:
Neonatal hypothermia poses an increased risk of infection, hypoglycemia, metabolic dysfunction, and mortality, particularly in preterm or low birthweight (LBW) infants. However, early detection of hypothermia and prompt thermoregulation can mitigate these effects thus, the need for continuous neonatal temperature monitoring. The BEMPU TempWatch is a small bracelet designed for continuous temperature monitoring for neonates. When the body temperature falls below 36.5˚C, the bracelet generates an alarm sound and flashes an orange light, indicating hypothermia. This study aimed to assess the validity of the BEMPU TempWatch in detecting hypothermia in a clinical setting in Ghana using sensitivity and specificity. Additionally, the study sought to identify factors associated with misclassification using logistic regression analysis. A standardized questionnaire collected information about the mother, pregnancy, delivery, and neonate. The BEMPU TempWatch was placed on the wrist of the neonate, and over a 24-hour follow-up period, a nurse took 4-hourly axillary temperature readings using a digital thermometer. Whenever the device's alarm sounded, a nurse immediately checked and recorded the axillary temperature, undertook necessary clinical actions, and rechecked after 30 minutes. Among the 249 neonates included in the study, 57.0% were female, 12.5% were extremely LBW, and 13.7% were extremely preterm. Based on 1,973 temperature readings, the sensitivity of the BEMPU TempWatch in detecting hypothermia was 67.8%, and the specificity was 95.9%. The sensitivity was lower among neonates being treated in incubators (58.4%) compared to those not (82.7%). Sensitivity was higher among neonates with LBW (1,500-2,500g) (73.5%) than very or extremely LBW neonates (<1,500g) (62.8%). The results showed that the BEMPU TempWatch had significantly fewer misclassifications among neonates who were not treated in an incubator, received only breastmilk, and were not born extremely preterm. Further studies are warranted to evaluate the effectiveness of the BEMPU TempWatch on neonatal health outcomes.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.