Related Experiment Video
Updated: Jul 12, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Comparison of voltages between atria: differences in sinus rhythm and atrial fibrillation
Alexander P Bates1,2, John Paisey3, Arthur Yue3
1Department of Cardiology, University Hospital Southampton NHS Foundation Trust, Tremona Road, Southampton, UK. alexanderbates@nhs.net.
Background:
Ultra high-density mapping systems allow for comparison of atrial electroanatomical maps in unprecedented detail. Atrial scar determined by voltages and surface area between atria, rhythm and atrial fibrillation (AF) types was assessed.
Methods:
Left (LA) and right atrial (RA) maps were created using Rhythmia HDx in patients listed for ablation for paroxysmal (PAF, sinus rhythm (SR) maps only) or persistent AF (PeAF, AF and SR maps). Electrograms on corresponding SR/AF maps were paired for direct comparison. Percentage surface area of scar was assigned low- (LVM, ≤ 0.05 mV), intermediate- (IVM, 0.05-0.5 mV) or normal voltage myocardium, (NVM, > 0.5 mV).
Results:
Thirty-eight patients were recruited generating 96 maps using 913,480 electrograms. Paired SR-AF bipolar electrograms showed fair correlation in LA (Spearman's ρ = 0.32) and weak correlation in RA (ρ = 0.19) and were significantly higher in SR in both (LA: 0.61 mV (0.20-1.67) vs 0.31 mV (0.10-0.74), RA: 0.68 mV (0.19-1.88) vs 0.47 mV (0.14-1.07), p < 0.0005 both). Voltages were significantly higher in patients with PAF over PeAF, (LA: 1.13 mV (0.39-2.93) vs 0.52 mV (0.16-1.49); RA: 0.93 mV (0.24-2.46) vs 0.57 mV (0.17-1.69)). Minimal differences were seen in electrogram voltages between atria. Significantly more IVM/LVM surface areas were seen in AF over SR (LA only, p < 0005), and PeAF over PAF (LA: p = 0.01, RA: p = 0.04). There was minimal difference between atria within patients.
Conclusions:
Ultra high-density mapping shows paired electrograms correlate poorly between SR and AF. SR electrograms are typically (but not always) larger than those in AF. Patients with PeAF have a lower global electrogram voltage than those with PAF. Electrogram voltages are similar between atria within individual patients.
More Related Videos
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Dysrhythmias II: Classification of Tachyarrhythmias