Intravenous Medication Administration Safety with Smart Infusion Pumps in the Neonatal Intensive Care Unit: An
Kumiko O Schnock1,2, Sara E Rostas3, Catherine S Yoon4
1Division of General Internal Medicine and Primary Care, Brigham and Women's Hospital, 1620 Tremont Street, OBC-3, Boston, MA, 02120-1613, USA. kschnock@bwh.harvard.edu.
Smart infusion pumps in neonatal intensive care units (NICUs) show promise for medication safety. Most errors stemmed from non-compliance, highlighting the need for policy changes and better adherence to smart pump technology.
Area of Science:
- Neonatal Intensive Care Unit (NICU) Medication Safety
- Health Informatics
- Patient Safety
Background:
- Neonatal intensive care units (NICUs) care for vulnerable infants, where medication errors pose significant risks.
- Smart infusion pumps are used to enhance medication administration safety, but their impact in NICUs remains uncertain.
Purpose of the Study:
- To investigate the incidence and types of intravenous (IV) medication administration errors in a NICU setting.
- To evaluate the role of smart infusion pump technology in medication safety within the NICU.
Main Methods:
- An observational, prospective point-prevalence study was conducted over 48 days within a 3-month period in 2019.
- Intravenous medication administrations were observed in 441 patients at an academic medical center in the USA.
Main Results:
- A total of 905 IV medication administrations were observed, with 130 errors (14.4 per 100 administrations).
- The most common errors included incorrect drug library entries (5.3 per 100), unauthorized medications (0.7 per 100), and wrong doses (0.6 per 100).
- 68 errors (7.5 per 100) were classified as unlikely to cause harm, and no patient harm was identified.
Conclusions:
- Medication errors unique to NICU populations were identified, but no patient harm occurred.
- Non-compliance with smart pump technology was the primary cause of errors.
- Enhancing NICU medication safety requires policy changes and improved adherence to smart pump utilization.
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Routes of Drug Administration: Parenteral
The intravenous route (IV) of drug administration can be further categorized into two types. The bolus injection administers the entire dose rapidly, while an intravenous infusion slowly delivers smaller doses steadily.
The IV route is often...