Verification and Validation of Lower Body Negative Pressure as a Non-Invasive Bioengineering Tool for Testing
Victor A Convertino1,2,3, Eric J Snider4, Sofia I Hernandez-Torres4
1Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA.
Abstract:
Since hemorrhage is a leading cause of preventable death in both civilian and military settings, the development of advanced decision support monitoring capabilities is necessary to promote improved clinical outcomes. The emergence of lower body negative pressure (LBNP) has provided a bioengineering technology for inducing progressive reductions in central blood volume shown to be accurate as a model for the study of the early compensatory stages of hemorrhage. In this context, the specific aim of this study was to provide for the first time a systematic technical evaluation to meet a commonly accepted engineering standard based on the FDA-recognized Standard for Assessing Credibility of Modeling through Verification and Validation (V&V) for Medical Devices (ASME standard V&V 40) specifically highlighting LBNP as a valuable resource for the safe study of hemorrhage physiology in humans. As an experimental tool, evidence is presented that LBNP is credible, repeatable, and validated as an analog for the study of human hemorrhage physiology compared to actual blood loss. The LBNP tool can promote the testing and development of advanced monitoring algorithms and evaluating wearable sensors with the goal of improving clinical outcomes during use in emergency medical settings.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure in the Leg
Preparation:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...