Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Utilizing ablation volume for calibration in LA-ICP-MS mapping to address variations in ablation rates within and
Kristina Mervič1, Johannes T van Elteren1, Marjan Bele2
1Department of Analytical Chemistry, National Institute of Chemistry, Hajdrihova 19, Ljubljana, 1000, Slovenia.
Abstract:
Quantification in 2D LA-ICP-MS mapping generally requires matrix-matched standards to minimize issues related to elemental fractionation. In addition, internal standardization is commonly applied to correct for instrumental drift and fluctuation, whereas also differences in ablated mass can be rectified for samples that cannot be sectioned and subjected to total ablation. However, it is crucial that the internal standard element is homogeneously distributed in the sample and that the laser light absorptivity is uniform over the surface. As in practice these requirements are often not met, this work will focus on correction of ablation rate differences within/between samples and standards by normalizing the element maps using the associated ablation volume per pixel as measured by optical profilometry. Due to the volume correction approach the element concentrations are no longer defined as mass per mass concentrations (in μg g-1) but by mass per volume concentrations (in μg cm-3), which can be interconverted in case matrix densities are known. The findings show that ablation volume-aided calibration yields more accurate element concentrations in 2D LA-ICP-MS maps for a decorative glass with highly varying elemental concentrations (murrina). This research presents a warning that if there are variations in ablation rates between samples and standards within and across matrices, even when their sensitivities are the same, generic LA-ICP-MS calibration protocols may not accurately depict the actual element concentrations.
More Related Videos
12:03Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab