A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Bi-parametric prostate MRI with a recall system for contrast enhanced imaging: Improving accessibility while
Iffat Rehman1, Emily Pang1, Alison C Harris1
1Department of Radiology, Vancouver General Hospital, University of British Columbia, 899 West 12(th) Avenue Vancouver, BC V5Z 1M9, Canada.
Purpose:
To review the efficacy of a recall system for bi-parametric non-contrast prostate MRI (bp-MRI).
Methods:
A bi-parametric protocol was instituted in July 2020 for all patients who had a prostate MRI requested, excluding those after treatment of prostate cancer, patients with hip prosthesis or pacemaker, and those who lived out-of-town. The protocol consisted of tri-planar T2-weighted and diffusion weighted images (DWI) (b = 50, 800 s/mm2 for ADC map; b = 1,500 s/mm2 acquired separately) in accordance with the Prostate Imaging Reporting & Data system (PI-RADS) v2.1 guidelines. After interpretation of bp-MRI exams, patients with equivocal (PI-RADS 3) lesions in peripheral zone (PZ) or any technical limitations were recalled for contrast administration.
Results:
Out of 909 bp-MRI scans performed from July 2020 to April 2021, only 52 (5.7 %) were recalled, of which 46 (88.5 %) attended. Amongst these, 41/52 (78.8 %) were recalled for PZ PI-RADS 3 lesions, while the rest of 11 (21.2 %) cases were recalled for technical reasons. Mean time to subsequent recall scan was 11.6 days. On assessment of post-contrast imaging, 29/46 (63 %) cases were upgraded to PI-RADS 4 while 17/46 (37 %) remained PI-RADS 3. This system avoided contrast-agent use in 857 patients, with contrast cost savings of €64,620 (US$68,560) and 214 hours 15 minutes of scanner time was saved. This allowed 255 additional bp-MRI scans to be performed, reducing the waitlist from 1 year to 2-3 weeks.
Conclusion:
A bi-parametric prostate MRI protocol with a robust recall system for contrast administration not only saved time eliminating the marked backlog but was also more cost efficient without compromising the quality of patient care.