Background:
There is limited evidence supporting the value of morphological parameters on post-reduction magnetic resonance imaging (MRI) to predict long-term residual acetabular dysplasia (RAD) after closed or open reduction for the treatment of developmental dysplasia of the hip (DDH).
Methods:
We performed a retrospective study of 42 patients (47 hips) undergoing open or closed reduction with a minimum 10 years of follow-up; 39 (83%) of the hips were in female patients, and the median age at reduction was 6.3 months (interquartile range [IQR], 3.3 to 8.9 months). RAD was defined as additional surgery with an acetabular index >2 standard deviations above the age- and sex-specific population-based mean value or Severin classification grade of >2 at last follow-up. Acetabular version and depth-width ratio, coronal and axial femoroacetabular distance, cartilaginous and osseous acetabular indices, transverse ligament thickness, and the thickness of the medial and lateral (limbus) acetabular cartilage were measured on post-reduction MRI.
Results:
At the time of final follow-up, 24 (51%) of the hips had no RAD; 23 (49%) reached a failure end point at a median of 11.4 years (IQR, 7.6 to 15.4 years). Most post-reduction MRI measurements, with the exception of the cartilaginous acetabular index, revealed a significant distinction between the group with RAD and the group with no RAD when mean values were compared. The coronal femoroacetabular distance (area under the receiver operating characteristic curve [AUC], 0.95; 95% confidence interval [CI], 0.90 to 1.00), with a 5-mm cutoff, and limbus thickness (AUC, 0.91; 95% CI, 0.83 to 0.99), with a 4-mm cutoff, had the highest discriminatory ability. A 5-mm cutoff for the coronal femoroacetabular distance produced 96% sensitivity (95% CI, 78% to 100%), 83% specificity (95% CI, 63% to 95%), 85% positive predictive value (95% CI, 65% to 96%), and 95% negative predictive value (95% CI, 76% to 100%). A 4-mm cutoff for limbus thickness had 96% sensitivity (95% CI, 78% to 100%), 63% specificity (95% CI, 41% to 81%), 71% positive predictive value (95% CI, 52% to 86%), and 94% negative predictive value (95% CI, 70% to 100%).
Conclusions:
Coronal femoroacetabular distance, a quantitative metric assessing a reduction's concentricity, and limbus thickness, a quantitative metric assessing the acetabulum's cartilaginous component, help to predict hips that will have RAD in the long term after closed or open reduction.
Level Of Evidence:
Diagnostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
More Related Videos
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
08:40Author Spotlight: A Novel 3D-Printed Titanium Implant for Minimally Invasive Treatment of Hip Dysplasia in Young Dogs
Published on: April 19, 2024
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI