FLEXGRID - A novel smart grid architecture that facilitates high-RES penetration through innovative flexibility

Nikolaos Efthymiopoulos1, Prodromos Makris1, Georgios Tsaousoglou1

  • 1Institute of Communication and Computer Systems, National Technical University of Athens, Athens, 15773, Greece.

Open Research Europe
|November 23, 2023
PubMed

Related Concept Videos

Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
211
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
119
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
241
Electrical Power01:07

Electrical Power

Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
1.6K
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
271