QGWFQS: A Queue-Group-Based Weight Fair Queueing Scheduler on FPGA

Yunfei Guo1,2, Zhichuan Guo1,2, Xiaoyong Song1,2

  • 1National Network New Media Engineering Research Center, Institute of Acoustics, Chinese Academy of Sciences, No. 21, North Fourth Ring Road, Haidian District, Beijing 100190, China.

Micromachines
|November 25, 2023
PubMed

Related Concept Videos

Parallel Processing01:20

Parallel Processing

The brain processes sensory information rapidly due to parallel processing, which involves sending data across multiple neural pathways at the same time. This method allows the brain to manage various sensory qualities, such as shapes, colors, movements, and locations, all concurrently. For instance, when observing a forest landscape, the brain simultaneously processes the movement of leaves, the shapes of trees, the depth between them, and the various shades of green. This enables a quick and...
155
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
119
Biasing of FET01:22

Biasing of FET

Biasing a Junction Field Effect Transistor (JFET) is crucial for setting operational parameters and ensuring efficient functioning in electronic circuits. JFETs are characterized by using a single carrier type in N-channel or P-channel configurations, where the channel is surrounded by PN junctions. These junctions are central to the device's ability to control current flow.
In an N-channel JFET, the structure consists of N-type material forming the channel on a P-type substrate, with the...
284
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
166
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
122
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
204