Factory-Calibrated Continuous Glucose Monitoring Systems in Type 1 Diabetes: Accuracy during In-Clinic Exercise and
Sissel Banner Lundemose1, Christian Laugesen1, Ajenthen Gayathri Ranjan1
1Steno Diabetes Center Copenhagen, Clinical Research, Diabetes Technology Research, Borgmester Ib Juuls Vej 83, DK-2730 Herlev, Denmark.
Abstract:
Continuous glucose monitors (CGMs) are valuable tools for improving glycemic control, yet their accuracy might be influenced by physical activity. This study sought to assess the accuracy of the three latest factory-calibrated CGM systems available in Europe at the time the study was conducted, both during aerobic exercise and in typical daily scenarios. The accuracy evaluation, based on metrics such as the median absolute relative difference (MARD) and point and rate error-grid analyses (PEGA and REGA), involved 13 adults with type 1 diabetes. Participants wore all sensors during a 1 h in-clinic exercise session followed by a subsequent 3-day home period, with blood glucose measurements serving as reference values in both contexts. During exercise, no statistically significant differences in MARD were observed (Dexcom G6: 12.6%, Guardian 4: 10.7%, and Freestyle Libre 2: 17.2%; p = 0.31), and similarly, no significant differences emerged in PEGA-zone-AB (100%, 100%, 96.8%; p = 0.37). Nevertheless, Freestyle Libre 2 showed comparatively diminished accuracy in estimating glucose trends during exercise (REGA-zone-AB: 100%, 93.0%, 73.3%; p = 0.0003). In the home environment, Freestyle Libre 2 exhibited a significantly higher MARD when compared to the other systems (10.2%, 11.9%, 16.7%, p = 0.02). Overall, Dexcom G6 and Guardian 4 demonstrated superior accuracy in both exercise and daily life scenarios compared to Freestyle Libre 2.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Diabetes: Symptoms, Diagnosis, and Complications
Hypoglycemia and Glucagon
Errors occurring during blood pressure monitoring
Several factors...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...