Liquid Crystal Polymer-Based Miniaturized Fully Implantable Deep Brain Stimulator.
Seung-Hee Ahn1, Chin Su Koh2, Minkyung Park2
1Department of Electrical and Computer Engineering, College of Engineering, Seoul National University, Seoul 08826, Republic of Korea.
Polymers
|November 25, 2023
Summary
Researchers developed a miniaturized, implantable deep brain stimulation (DBS) system for rats. This battery-free device, made from liquid crystal polymer (LCP), effectively reduced neuropathic pain in animal models.
Area of Science:
- Biomedical Engineering
- Neuroscience
- Materials Science
Background:
- Deep brain stimulation (DBS) systems face challenges in miniaturization for reduced invasiveness.
- Integrating stimulators and electrodes into compact, wireless-charging units is crucial for advanced DBS.
- Current DBS systems often require bulky external components or batteries, limiting animal behavior.
Purpose of the Study:
- To develop a miniaturized, fully implantable, and battery-free DBS system for preclinical research in rats.
- To demonstrate the feasibility of integrating a stimulator, receiver coil, and microelectrode array into a compact LCP package.
- To validate the system's efficacy in treating neuropathic pain in an animal model.
Main Methods:
- Fabrication of a dome-shaped LCP package (13 mm diameter, 5 mm height) housing the stimulator circuit, receiver coil, and an 8-channel microelectrode array.
- Utilizing wireless powering and control via an inductive link for untethered animal movement.
- Monolithic encapsulation of the multilayered LCP substrate using a specialized spot-welding process.
- In vivo validation using a neuropathic pain model in rats.
Main Results:
- Successful development of a miniaturized, fully implantable, and battery-free DBS device.
- Demonstrated wireless powering and control, enabling free behavior of untethered rats.
- Significant increase in the mechanical withdrawal threshold in rats treated with the DBS system, indicating pain reduction.
Conclusions:
- The developed LCP-based miniaturized DBS system is effective for preclinical research.
- The battery-free, wireless design significantly enhances animal freedom and reduces invasiveness.