Related Experiment Video
Updated: Jul 10, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
CEST and nuclear Overhauser enhancement imaging with deep learning-extrapolated semisolid magnetization transfer
Hye-Young Heo1, Munendra Singh1, Vivek Yedavalli1
1The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, Maryland, USA.
Purpose:
To develop a novel MR physics-driven, deep-learning, extrapolated semisolid magnetization transfer reference (DeepEMR) framework to provide fast, reliable magnetization transfer contrast (MTC) and CEST signal estimations, and to determine the reproducibility and reliability of the estimates from the DeepEMR.
Methods:
A neural network was designed to predict a direct water saturation and MTC-dominated signal at a certain CEST frequency offset using a few high-frequency offset features in the Z-spectrum. The accuracy, scan-rescan reproducibility, and reliability of MTC, CEST, and relayed nuclear Overhauser enhancement (rNOE) signals estimated from the DeepEMR were evaluated on numerical phantoms and in heathy volunteers at 3 T. In addition, we applied the DeepEMR method to brain tumor patients and compared tissue contrast with other CEST calculation metrics.
Results:
The DeepEMR method demonstrated a high degree of accuracy in the estimation of reference MTC signals at ±3.5 ppm for APT and rNOE imaging, and computational efficiency (˜190-fold) compared with a conventional fitting approach. In addition, the DeepEMR method achieved high reproducibility and reliability (intraclass correlation coefficient = 0.97, intersubject coefficient of variation = 3.5%, and intrasubject coefficient of variation = 1.3%) of the estimation of MTC signals at ±3.5 ppm. In tumor patients, DeepEMR-based amide proton transfer images provided higher tumor contrast than a conventional MT ratio asymmetry image, particularly at higher B1 strengths (>1.5 μT), with a distinct delineation of the tumor core from normal tissue or peritumoral edema.
Conclusion:
The DeepEMR approach is feasible for measuring clean APT and rNOE effects in longitudinal and cross-sectional studies with low scan-rescan variability.
Related Concept Videos
Magnetic Resonance Imaging
Nuclear Overhauser Enhancement (NOE)
NMR Spectrometers: Resolution and Error Correction
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Magnetic Resonance