Related Experiment Video
Updated: Jul 9, 2025

Multiplexed Fluorescent Microarray for Human Salivary Protein Analysis Using Polymer Microspheres and Fiber-optic Bundles
Published on: October 10, 2013
Human Saliva as a Substitute Diagnostic Medium for the Detection of Oral Lesions Using the Stokes Shift Spectroscopy:
Pavan Kumar1,2, Asima Pradhan2
1Department of BSH, Faculty of Engineering and Technology (FEAT), Datta Meghe Institute of Higher Education and Research (DMIHER), DU, Sawangi - 442001, India.
Objective:
Our objective in the present study is to detect oral mucosal lesions non-invasively by probing two solutions with reference to diagnostic technique and non-invasive media. In the diagnostic technique, Stokes shift (SS) spectroscopy (SSS) has been utilized for the detection of oral lesions. In the diagnostic media, human oral tissue and saliva are included.
Methods:
SS measurements are carried out on oral squamous cell carcinoma (OSCC), dysplastic (precancer), and normal/control tissue and saliva samples. Measurements are performed on 86 tissue and 86 saliva samples using the commercially available spectrofluorometer. Offset wavelength of 120 nm, which is the Stoke shift of nicotinamide adenine dinucleotide (NADH) has been selected over the other offsets (i.e., 20, 40, 70 and 90 nm).
Result:
Presence of tryptophan, collagen, NADH, and flavin adenine dinucleotide (FAD) bands were noticed in the SS spectra of tissue. Like the tissue spectra, presence of these bands was also found in the SS spectra of saliva except the collagen band. Classification among the samples accomplished by the make use of multivariate analysis methods. In the multivariate analysis methods, principal component analysis (PCA) is applied first on SS data of tissue and saliva and then Mahalanobis distance (MD) model and receiver operating characteristic (ROC) analysis employed successively. Overall accuracy values of 94.91 %, 84.61 %, and 85.24 % were obtained among OSCC to normal, dysplasia to normal, and OSCC to dysplasia for tissue samples and 88.46 %, 90.16 % and 94.91 % accuracy values were obtained for saliva using the SS spectroscopy.
Conclusion:
Obtained results of human saliva are equivalent to human oral tissue using the SS spectroscopy. It indicates that saliva may be utilized as a substitute diagnostic medium and SS spectroscopy as a diagnostic technique for non-invasive detection of oral lesions at the primarily stage.
More Related Videos
08:37Sampling Human Indigenous Saliva Peptidome Using a Lollipop-Like Ultrafiltration Probe: Simplify and Enhance Peptide Detection for Clinical Mass Spectrometry
Published on: August 7, 2012
05:42Author Spotlight: Unlocking the Mysteries of Oral Potential Malignancies
Published on: August 11, 2023
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Serum Laboratory Studies, Stool Test, Breath Test