Ground flat-field calibration of a space astronomical telescope using a spatial time-sharing calibration method
Abstract:
Preflight ground flat-field calibration is significant to the development phase of space astronomical telescopes. The uniformity of the flat-field illumination reference source seriously decreases with the increasing aperture and the telescope's field of view, directly affecting the final calibration accuracy. To overcome this problem, a flat-field calibration method that can complete calibration without a traditional flat-field illumination reference source is proposed on the basis of the spatial time-sharing calibration principle. First, the characteristics of the flat field in the spatial domain taken by the space astronomical telescope are analyzed, and the flat field is divided into large-scale flat (L-flat) and pixel-to-pixel flat (P-flat). They are then obtained via different calibration experiments and finally combined with the data fusion process. L-flat is obtained through star field observations and the corresponding L-flat extraction algorithm, which can obtain the best estimation of L-flat based on numerous photometry samples, thereby effectively improving calibration accuracy. The simulation model of flat-field calibration used for accuracy analysis is established. In particular, the error sources or experimental parameters that affect the accuracy of L-flat calibration are discussed in detail. Results of the accuracy analysis show that the combined uncertainty of the proposed calibration method can reach 0.78%. Meanwhile, experiments on an optic system with a Φ142mm aperture are performed to verify the calibration method. Results demonstrate that the RMS values of the residual map are 0.720%, 0.565%, and 0.558% at the large-, middle-, and small-scale, respectively. The combined calibration uncertainty is 0.88%, which is generally consistent with the results of the accuracy analysis.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Field Application of Global Positioning System
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Types of Global Positioning System Surveys
Adjusting a Traverse
Influence of Earth's Curvature and Atmospheric Refraction on Leveling