Related Experiment Video
Updated: Jul 8, 2025

Size Exclusion Chromatography for Separating Extracellular Vesicles from Conditioned Cell Culture Media
Published on: May 13, 2022
Evaluation of multi-solvent size exclusion chromatography columns packed with sub-2 μm particles for the
Sensen Shen1, Mubasher Bashir2, Steve Huysman2
1Dow, Analytical Science, 201203 Shanghai, China.
Abstract:
With the recent development of small particle stationary-phases and dedicated instrumentation, the combination of size-exclusion chromatography (SEC) with ultra-high performance liquid chromatography (UHPLC) technology has been realized. It opened up a new polymer analysis technique called UHP-SEC. Although high resolution and fast analysis can be achieved, the multi-solvent suitability for a given column was limited to either organic or aqueous eluents. In this work, the capability of novel SEC columns (AdvanceBio SEC columns) packed with 1.9 μm particles for the characterization of synthetic polymers in organic solvents as well as the multi-solvent compatibility for organic and aqueous eluents have been demonstrated. About six times faster separation for both polystyrene (PS) and polyethylene glycol (PEG) with good peak shape and repeatability were achieved in comparison with standard SEC columns at comparable resolution. Especially for PEG, in contrast to other SEC columns, this column could provide close-to-accurate determination of molecular weights with tetrahydrofuran (THF) as mobile phase. Good reproducibility was obtained after switching several times from water to THF and vice versa with RSD% in retention times less than 0.5 %. Different samples such as polyols, isocyanates and additives can also be analyzed for molecular weight and distribution or composition determination. Volume overload, especially with injection volumes higher than 10 µL needs to be considered. This new column offers a powerful choice for oligomer and polymer analysis with both aqueous and organic mobile phase. Ultimately, hyphenating SEC columns to various detectors can enable more information regarding chemical composition, molecular weight, concentration, and structure.
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...