Photoplethysmography-based cuffless blood pressure estimation: an image encoding and fusion approach
Yinsong Liu1, Junsheng Yu1,2,3, Hanlin Mou4
1Department of School of Electronic Engineering, Beijing University of Posts and Telecommunication, Beijing 100876, People's Republic of China.
None:
Objective.Photoplethysmography (PPG) is a promising wearable technology that detects volumetric changes in microcirculation using a light source and a sensor on the skin's surface. PPG has been shown to be useful for non-invasive blood pressure (BP) measurement. Deep learning-based BP measurements are now gaining popularity. However, almost all methods focus on 1D PPG. We aimed to design an end-to-end approach for estimating BP using image encodings from a 2D perspective.Approach.In this paper, we present a BP estimation approach based on an image encoding and fusion (BP-IEF) technique. We convert the PPG into five image encodings and use them as input. The proposed BP-IEF consists of two parts: an encoder and a decoder. In addition, three kinds of well-known neural networks are taken as the fundamental architecture of the encoder. The decoder is a hybrid architecture that consists of convolutional and fully connected layers, which are used to fuse features from the encoder.Main results.The performance of the proposed BP-IEF is evaluated on the UCI database in both non-mixed and mixed manners. On the non-mixed dataset, the root mean square error and mean absolute error for systolic BP (SBP) are 13.031 mmHg and 9.187 mmHg respectively, while for diastolic BP (DBP) they are 5.049 mmHg and 3.810 mmHg. On the mixed dataset, the corresponding values for SBP are 4.623 mmHg and 3.058 mmHg, while for DBP the values are 2.350 mmHg and 1.608 mmHg. In addition, both SBP and DBP estimation on the mixed dataset achieved grade A compared to the British Hypertension Society standard. The DBP estimation on the non-mixed dataset also achieved grade A.Significance.The results indicate that the proposed approach has the potential to improve on the current mobile healthcare for cuffless BP measurement.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: