Related Experiment Video
Updated: Jul 8, 2025

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Single particle inductively coupled plasma mass spectrometry and its variations for the analysis of nanoparticles
Zichao Zhou1, Diane Beauchemin1
1Queen's University, Department of Chemistry, 90 Bader Lane, Kingston, ON K7L 3N6, Canada. diane.beauchemin@queensu.ca.
Abstract:
Single particle inductively coupled plasma mass spectrometry (spICPMS) can count and weigh metal-containing nanoparticles (NPs), enabling their sizing if their geometry, density, and composition are known. With a nebulizer and a spray chamber for sample introduction, both the sample uptake rate and the transport efficiency must be determined when calibrating with solutions. In contrast, flow injection (FI) and mono-segmented flow analysis (MSFA) coupled to spICPMS do not need determination of the transport efficiency and sample uptake rate for accurate NP mass measurement. Correcting for the significant settling time on some instruments is also discussed, as well as calibration through signal integration instead of averaging, which eliminates the need to measure the transport efficiency when seeking NP mass. Nitrogen added to the outer plasma gas can reduce the background for the determination of P, S, Ca and Fe. Infrared heating of the sample introduction system provides 100% transport efficiency, enabling accurate particle mass and concentration measurements without measurement of transport efficiency.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Atomic Emission Spectroscopy: Lab

