Automated audit of hospital oxygen use devised during the COVID-19 pandemic
Ronan O'Driscoll1, Nawar Diar Bakerly2
1Respiratory Medicine, Salford Royal Hospital, Northern Care Alliance NHS Foundation Trust, Salford, UK ronan.o'driscoll@nca.nhs.uk.
Background:
The British Thoracic Society (BTS) has organised intermittent audits of hospital oxygen use in UK hospitals since 2008. Manual audits are time-consuming and subject to human errors. Oxygen prescribing and bedside observations including National Early Warning Scores (NEWS2 scores) are undertaken within an integrated electronic medical record (EMR) at this hospital.
Methods:
The hospital's Business Information team were commissioned in late 2019 to devise a bespoke automated audit of oxygen prescribing and use. A summary report displays the oxygen saturation alongside the oxygen prescription status of every patient in the hospital except for critical care units which do not use NEWS2. The display has a 'traffic-light' colour scheme (green within target range, amber or red if below range or if above range on supplemental oxygen), with a graph showing oxygen use and saturation levels for patients with each prescribed target range. Clinicians can access raw data including oxygen saturation, oxygen device and flow rate for each individual patient.
Results:
Over 51 audits involving 34 352 sets of observations, an average of 6.0% involved use of oxygen and 88.6% of these had a valid oxygen prescription. During the first wave of the COVID-19 pandemic in spring 2020, the monthly percentage of observations involving oxygen use increased to a peak of 10.4% followed by a rise to 10.6% during the second wave and 7.4% during the third (Omicron) wave. Oxygen use returned to baseline after each wave.
Conclusions:
In hospitals with integrated EMRs, it is possible to automate all fundamental aspects of the BTS oxygen audits and to monitor oxygen use at individual patient level and a hospital-wide level. This could be particularly valuable during major events such as the COVID-19 pandemic. This methodology could be extended to other clinical audits where the audit questions relate to routinely collected EMR data.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...