The Effect of Nonstress Device Noise Level on Stress Parameters in Primigravid Women: A Randomized Controlled Trial
Turan Ayşenur1,2, Gençtürk Nuran3, Kaya Cihan4
1Department of Midwifery, Istanbul University-Cerrahpasa, Institute of Graduate Studies, Midwifery Doctorate Program, Istanbul, Turkey.
Introduction:
This study evaluated the effect of the noise level of the nonstress test (NST) device on stress parameters in primigravid women.
Methods:
A total of 44 pregnant women participated in a randomized clinical trial between February and October, 2021. The participants were divided randomly into 4 equal groups using an automated web-based randomization system and ensuring allocation concealment: the control group (NST device volume turned off), intervention group I (1-35 dB(A)), intervention group II (36-60 dB(A)), and intervention group III (61 dB(A) and above). A data collection form was used to record personal information and stress parameters. Stress parameters (blood pressure, heart rate, oxygen saturation [SpO2], blood glucose, salivary cortisol, and salivary adrenocorticotropic hormone [ACTH]) levels were measured pretest (0-2 minutes before NST starts), midtest (at 10 minutes of the NST), and posttest (within 0-2 minutes after NST was finished). The study was registered at ClinicalTrials.gov (identifier: NCT05488704).
Results:
NST sound levels above 35 dB(A) increased the average cortisol and ACTH levels in the posttest. NST sound levels were positively correlated with posttest cortisol (r = .448) and posttest glucose (r = .302). There was interaction effect on heart rate, glucose, and cortisol level by time, indicating that the intervention groups experienced a significant acceleration in heart rate, glucose, and cortisol level after a noise intervention compared with the control group.
Discussion:
Midwives should continue applying NST below 36 dB(A), considering the factors that may induce stress during the NST process.
More Related Videos
06:19Author Spotlight: Implications of Non-Nutritive Sucking on Speech Emergence and Infant Development
Published on: April 19, 2024
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Introduction to Stress and Lifestyle
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes