Related Experiment Video
Updated: Jul 5, 2025

09:30
Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
19.6K
Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver.
Juan A Vasquez1,2, Marissa Brown1,2, Mary Woolsey2
1Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA.
Journal of Magnetic Resonance Imaging : JMRI
|January 19, 2024
Summary
Simultaneous multislice (SMS) MRI significantly improves intravoxel incoherent motion (IVIM) parameter estimation for liver fibrosis evaluation by reducing variability and scan time compared to echo-planar imaging (EPI). This technique enhances diagnostic accuracy for hepatic steatosis.
Area of Science:
- Radiology and Medical Imaging
- Biophysics
- Gastroenterology
Background:
- Intravoxel incoherent motion (IVIM) diffusion-weighted MRI (DWI) shows promise for assessing hepatic fibrosis.
- However, variations in image acquisition techniques can impact the reliability of IVIM diffusion parameter estimates.
- Standard echo-planar imaging (EPI) may introduce distortions and variability in abdominal DWI.
Purpose of the Study:
- To minimize variability and maximize repeatability in abdominal DWI IVIM parameter estimation.
- To compare image quality and diffusion parameter repeatability between simultaneous multislice (SMS) and conventional EPI sequences.
- To optimize DWI acquisition techniques for reliable hepatic fibrosis assessment.
Main Methods:
- Prospective test-retest study comparing SMS and EPI DWI sequences with different respiratory triggering methods (breath-holding, navigator echo, respiratory triggering) at 3 Tesla.
- Analysis of IVIM parameters (fast-diffusion coefficient Df, fraction of fast diffusion f, slow-diffusion coefficient Ds) using a biexponential model.
- Evaluation of scan time, estimated signal-to-noise ratio (eSNR), and distortion ratios.
Main Results:
- Simultaneous multislice (SMS) acquisitions demonstrated significantly lower within-subject coefficients of variation (CoVs) for f and Ds compared to EPI.
- SMS techniques, particularly SMS-RT-HI, showed higher inter-observer agreement (ICC) for Ds estimation.
- SMS sequences offered higher eSNR, reduced distortion in the liver, and shorter scan times compared to EPI.
Conclusions:
- Simultaneous multislice (SMS) DWI acquisitions significantly reduce variability and improve repeatability for IVIM parameter estimation in the abdomen.
- SMS DWI provides superior image quality with higher eSNR and less distortion, making it advantageous for hepatic fibrosis assessment.
- The findings support SMS DWI as a more reliable and efficient technique for quantitative abdominal MRI compared to conventional EPI.