Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Phenylethylamine sensing at the electrified liquid-liquid interface. Can electrochemistry be used to follow the UHT
Konrad Rudnicki1, Karolina Sobczak1, Robert Karpiński1
1Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403 Lodz, Poland.
Abstract:
This study involved an investigation into the electrochemical characteristic of a few biogenic amines (BAs) occurring at the polarized interface between two immiscible electrolyte solutions (ITIES) with ion transfer voltammetry (ITV). The main focus of this research was the comprehensive electroanalytical and physicochemical analysis of phenylethylamine (PEA), allowing the determined of the formal Galvani potential of the ion transfer reaction (ΔorgaqΦ'), diffusion coefficients (D), formal free Gibbs energy of the ion transfer reaction (ΔG'aq→org) and water-1,2-dichloroethane partition coefficient (logPwater/DCEPEA). Furthermore, the collected data were employed to calculate analytical parameters, including voltametric detection sensitivity, limits of detection and the target analyte quantification. Moreover, the influence of the presence of 7 other BAs (histamine, spermine, spermidine, putrescine, cadaverine, tyramine and tryptamine) on the recorded signals originating from the PEA ion transfer was checked. The feasibility of the developed method was corroborated through experimentation with milk samples. Additionally, utilizing the devised methodology, an electrochemical assessment of the spoilage progression in milk samples was undertaken.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
12:11ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...