Related Experiment Video
Updated: Jul 5, 2025

Artificial Lung Device Priming for In Situ Fiber Bundle Surface Grafting
Published on: March 28, 2025
Outcomes of ECMO support with polypropylene membrane during pandemic times: a retrospective cohort study
Natalia Valenzuela-Faccini1, Claudia Poveda-Henao2,3, Catalina Flórez-Navas1
1Critical care resident, Universidad de La Sabana, Chía, Colombia.
Background:
The SARS-CoV-2 pandemic resulted in shortages of supplies, which limited the use of extracorporeal membrane oxygenation (ECMO) support. As a contingency strategy, polypropylene (PP) oxygenation membranes were used. This study describes the clinical outcomes in patients on ECMO with PP compared to poly-methylpentene (PMP) oxygenation membranes.
Methods:
Retrospective cohort of patients in ECMO support admitted between 2020 and 2021.
Results:
A total of 152 patients with ECMO support were included, 71.05% were men with an average age of 42 (SD 9.91) years. Veno-venous configuration was performed in 75.6% of cases. The PP oxygenation membranes required more changes 22 (63.1%), than the PMP Sorin® 24 (32,8%) and Euroset® 15 (31,9%) (p.0.022). The main indication for membrane change was low oxygen transfer for PP at 56.2%, Sorin® at 50%, and Euroset® at 14.8%. Renal replacement therapy was the most frequent complication with PP membrane in 22 patients (68.7%) Sorin® 25 patients (34.2%), and Euroset® 15 patients (31.9%) (p 0.001) without statistically significant differences in mortality.
Conclusion:
PP oxygenation membranes was a useful and feasible strategy. It allowed a greater disponibility of ECMO support for critically ill in a situation of great adversity during the SARS-CoV-2 pandemic.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes