Real-Time Temperature Prediction of Power Devices Using an Improved Thermal Equivalent Circuit Model and Application

Zhen Hu1, Man Cui2, Xiaohua Wu3

  • 1College of Automation, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.

Micromachines
|January 23, 2024
PubMed

Related Concept Videos

Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
433
Power in a Three-Phase Circuit01:15

Power in a Three-Phase Circuit

Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
324
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
261
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
179
Power Dissipated in a Circuit: Problem Solving01:15

Power Dissipated in a Circuit: Problem Solving

The equivalent resistance of a combination of resistors depends on their values and how they are connected.
The simplest combinations of resistors are series and parallel connections. In a series circuit, the first resistor's output current flows into the second resistor's input; therefore, each resistor's current is the same. Thus, the equivalent resistance is the algebraic sum of the resistances. The current through the circuit can be found from Ohm's law and is equal to the...
1.1K
Transformers with Off-Nominal Turns Ratios01:25

Transformers with Off-Nominal Turns Ratios

In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
157