We developed a new tool to assess the severity of osteoporotic vertebral fracture using radiographs of the spine. Our technique can be used in patient care by helping to stratify patients with osteoporotic vertebral fractures into appropriate treatment pathways. It can also be used for research purposes.
Purpose:
The aim of our study was to propose a semi-quantitative (SQ) grading scheme for osteoporotic vertebral fracture (OVF) on anteroposterior (AP) radiographs.
Methods:
On AP radiographs, the vertebrae are divided into right and left halves, which are graded (A) vertical rectangle, (B) square, (C) traverse rectangle, and (D) trapezoid; whole vertebrae are graded (E) transverse band or (F) bow-tie. Type A and B were compared with normal and Genant SQ grade 1 OVF, Type C and D with grade 2 OVF, and Type E and F with grade 3 OVF. Spine AP radiographs and lateral radiographs of 50 females were assessed by AP radiographs SQ grading. After training, an experienced board-certified radiologist and a radiology trainee assessed the 50 AP radiographs.
Results:
The height-to-width ratio of the half vertebrae varied 1.32-1.48. On lateral radiographs, 84 vertebrae of the 50 patients had OVFs (38 grade 1, 24 grade 2, and 22 grade 3). On AP radiographs, the radiologist correctly assigned 84.2%, 91.7%, and 77.2% and the trainee correctly assigned 68.4%, 79.2%, and 81.8% of grade 1, 2, and 3 OVFs, respectively. Compared with lateral radiographs, the radiologist had a weighted Kappa of 0.944 including normal vertebrae and 0.883 not including normal vertebrae, while the corresponding Kappa values for the trainee were 0.891 and 0.830, respectively.
Conclusion:
We propose a new semi-quantitative grading system for vertebral fracture severity assessment on AP spine radiographs.