Related Experiment Video
Updated: Jul 29, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Development and validation of a simple, fast and sensitive liquid chromatography-tandem mass spectrometry method to
Yan Song1, Runhao Xu1, Dan Liu2
1Department of Laboratory Medicine, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
Objective:
To develop and validate a rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to detect urinary free metanephrines and methoxytyramine, establishing reference intervals.
Methods:
Urine samples were diluted with isotope internal standard solution, then analyzed directly using tandem mass spectrometry with multiple reaction monitoring measurement and electrospray ionization source in positive ion mode. Analytical parameters including linearity, lower limit of quantitation, imprecision and accuracy of the method were evaluated. The reference intervals for urinary catecholamine metabolites were established by analyzing 24-h urine samples collected from 81 apparently healthy volunteers.
Results:
The analytical times for MN, NMN, and 3-MT were at 2.79, 2.80, and 2.74 min, respectively. The method displayed excellent linearity (r > 0.99) in the range of 1-1000 ng/mL, with lower limits of quantification (LLOQ) at 0.50 ng/mL for MN and NMN, and 0.25 ng/mL for 3-MT. The method's intra-day and inter-day imprecisions were less than 8 %. The method recovery ranged from 96.8% to 105.8 % for MN, 89.7%-106.4 % for NMN, and 93.5%-106.2 % for 3-MT. No carry-over was observed during the analysis of all analytes. The LC-MS/MS method was used to establish reference intervals in 24-h urine samples from 81 apparently healthy volunteers. There was no association of sex with urinary free metabolites.
Conclusion:
This study established a novel, fast and sensitive LC-MS/MS method for determining urinary free catecholamine metabolites, which could facilitate screening and diagnosis for catecholamine-related tumors more conveniently and quickly.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Urine Studies I: Urinalysis