Related Experiment Video
Updated: Jul 3, 2025

Quantitative and Qualitative Method for Sphingomyelin by LC-MS Using Two Stable Isotopically Labeled Sphingomyelin Species
Published on: May 7, 2018
The absolute δ18 O value for SLAP with respect to VSMOW reveals a much lower value than previously established
Anita Th Aerts-Bijma1, Albert C van Buuren1, Dipayan Paul1
1Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen, University of Groningen, Groningen, The Netherlands.
Rationale:
SLAP is one of the two calibration materials for the isotopic water scale. By consensus the established δ18 O value is -55.5‰, although several expert laboratories measure significantly more negative δ18 OSLAP values. The real δ18 OSLAP value as such does not influence the isotopic water scale; however, knowledge of the size of isotopic scale contraction in stable isotope measurements is vital for second-order isotopes. This study describes the quantification of δ18 OSLAP with respect to δ18 OVSMOW .
Methods:
SLAP-like water was quantitatively mixed with highly 18 O-enriched water to mimic VSMOW. The 18 O concentration was determined using an electron ionization quadrupole mass spectrometer. The isotopic composition of the SLAP-like and VSMOW-like waters was measured using an optical spectrometer, alongside original VSMOW and SLAP.
Results:
This study resulted in a much more negative δ18 O value for SLAP than expected. The averaged outcome of seven independent experiments is δ18 OSLAP = -56.33 ± 0.03‰. There is a large discrepancy between the actual isotopic measurements of even the most carefully operating isotope laboratories and the true δ18 O value.
Conclusions:
Although this finding as such does not influence the use of the VSMOW-SLAP scale, it raises the intriguing question of what we actually measure with our instruments and why even a fully corrected measurement can be so far off. Our result has consequences for issues like the transfer of δ18 O from and to the VPDB scale, various fractionation factors, and Δ17 O. The absolute 18 O abundance for SLAP was calculated as (1887.98 ± 0.43) × 10-6 based on the absolute 18 O abundance of VSMOW and the presented δ18 OSLAP in this paper.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Vapor Pressure Lowering
Dissolving a nonvolatile substance in volatile liquid results in a lowering of the liquid’s vapor pressure. This phenomenon can be explained by considering the effect of added solute molecules on the liquid's vaporization and condensation processes. To vaporize, solvent molecules must be present at the surface of the solution....

