Abstract:
This paper proposes a composite sliding mode control (SMC) to optimize the tracking performance and the anti-disturbance performance of permanent magnet synchronous machine (PMSM) speed regulation systems. The differential term in the control law can magnify the measurement noise, resulting in more discontinuity. To filter out the high frequency noise and make the control law smoother, the first-order differentiator (FOD) is employed to estimate the speed error and its derivative. Since the feedforward compensation can improve the robustness of the system, a disturbance observer (DOB) based on the sliding mode observer (SMO) is designed to reinforce the dynamic performance under disturbance variation. Under the effect of the feedforward compensation, chattering can be further weakened by decreasing the switching gain appropriately. Finally, the effectiveness of the proposed methods is confirmed by various experimental results.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...