Cervical artery tortuosity-a reliable semi-automated magnetic resonance-based method
Lukas Mayer-Suess1, Tamara Peball1, Sergiy Pereverzyev2,3
1Department of Neurology, Medical University of Innsbruck, Innsbruck, Austria.
A new method reliably assesses cervical artery tortuosity from MRA images, offering a simpler approach for diagnosing connective tissue disorders and studying spontaneous cervical artery dissection (sCeAD). This technique shows higher accuracy than visual appraisal.
Area of Science:
- Radiology
- Vascular Imaging
- Connective Tissue Disorders
Background:
- Assessing subclinical connective tissue disorders often requires complex methods.
- There is a need for more accessible clinical routine approaches.
- Cervical vessel tortuosity is linked to connective tissue disorders.
Purpose of the Study:
- To develop a reliable method for assessing cervical artery tortuosity.
- To create an approach applicable to clinical routine.
- To investigate the association between cervical artery tortuosity and spontaneous cervical artery dissection (sCeAD).
Main Methods:
- Utilized magnetic resonance angiography (MRA) images from the ReSect study cohort.
- Employed MATrix LABoratory, ITK-SNAP, and Vascular Modelling ToolKit for image segmentation and analysis.
- Assessed inter-user variability and compared results against expert neuro-radiologist visual appraisal.
Main Results:
- Analyzed 526 extracranial cervical arteries.
- Achieved inter-user variability below 0.5%.
- The developed method demonstrated superior accuracy compared to visual tortuosity appraisal, which underestimated the distance metric in a significant percentage of cases.
Conclusions:
- A reliable MRA-based method for assessing cervical artery tortuosity is presented.
- The method is suitable for clinical routine and research.
- It can aid future investigations into the correlation between sCeAD and connective tissue disorders.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System IV: CMRI