Related Experiment Video
Updated: Jul 10, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Improving image quality of triple-low-protocol renal artery CT angiography with deep-learning image reconstruction: a
1Department of Radiology, The Third Affiliated Hospital of Sun Yat-sen University, Tianhe District, Tianhe Road, 600, Guangzhou, 510620, China.
Aim:
To investigate the improvement in image quality of triple-low-protocol (low radiation, low contrast medium dose, low injection speed) renal artery computed tomography (CT) angiography (RACTA) using deep-learning image reconstruction (DLIR), in comparison with standard-dose single- and dual-energy CT (DECT) using adaptive statistical iterative reconstruction-Veo (ASIR-V) algorithm.
Materials And Methods:
Ninety patients for RACTA were divided into different groups: standard-dose single-energy CT (S group) using ASIR-V at 60% strength (60%ASIR-V), DECT (DE group) with 60%ASIR-V including virtual monochromatic images at 40 keV (DE40 group) and 70 keV (DE70 group), and the triple-low protocol single-energy CT (L group) with DLIR at high level (DLIR-H). The effective dose (ED), contrast medium dose, injection speed, standard deviation (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal aorta (AA), and left/right renal artery (LRA, RRA), and subjective scores were compared among the different groups.
Results:
The L group significantly reduced ED by 37.6% and 31.2%, contrast medium dose by 33.9% and 30.5%, and injection speed by 30% and 30%, respectively, compared to the S and DE groups. The L group had the lowest SD values for all arteries compared to the other groups (p<0.001). The SNR of RRA and LRA in the L group, and the CNR of all arteries in the DE40 group had highest value compared to others (p<0.05). The L group had the best comprehensive score with good consistency (p<0.05).
Conclusions:
The triple-low protocol RACTA with DLIR-H significantly reduces the ED, contrast medium doses, and injection speed, while providing good comprehensive image quality.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging