Related Experiment Video
Updated: Jul 1, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Temperature probe placement in very preterm infants during delivery room stabilization: an open-label randomized
Pranav R Jani1,2, Rajesh Maheshwari3,4, Hannah Skelton3,5
1Department of Neonatology, Westmead Hospital, Westmead, NSW, Australia. pranav.jani@sydney.edu.au.
Background:
Variation in practice exists for temperature probe positioning during stabilization of very preterm infants (<32 weeks gestation). We explored the influence of temperature probe sites on thermoregulation.
Methods:
An open-label, stratified, balanced, parallel, randomized trial was conducted. Inborn infants were randomly assigned temperature probe to the axilla or to the upper back. The primary outcome was normothermia (local range: 36.8-37.3 °C and World Health Organization (WHO) range: 36.5-37.5 °C) at admission to the neonatal intensive care unit.
Results:
Between 1 November 2018 and 4 July 2022, 178 infants were randomly assigned to one of the two sites (n = 89 each), 175 included in the final analysis. Normothermia (local range) was achieved for 39/87 infants (44.8%) assigned to the upper back compared to 28/88 infants (31.8%) assigned to the axilla [risk difference:13%; 95% CI -1.3-27.3]. Normothermia (WHO range) was achieved for 78/87 infants (89.7%) assigned to the upper back compared to 70/88 infants (79.6%) assigned to the axilla [risk difference:10.1%; 95% CI -0.5-20.7]. No infant recorded temperatures >38 °C or developed skin injury.
Conclusions:
In very preterm infants, upper back site was equally effective as the axilla in maintaining normothermia, with no increase in adverse events.
Clinical Trial Registration:
The study was registered with the Australian New Zealand Clinical Trials Registry (ACTRN12620000293965).
Impact:
Substantial variation in practice exists for the site of securing a temperature probe during delivery room stabilization of very preterm infants and the influence of temperature probe site on thermoregulation remains unknown. In this study, upper back site was equally effective as the axilla in maintaining normothermia, with no increase in adverse events. Clinicians could adopt upper back site for maintaining normothermia. This study may contribute data to future international participant data prospective meta analysis of randomized controlled trials worldwide on temperature probe positioning in very preterm infants, increasing translation of research findings to optimize thermoregulation and clinical outcomes.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...