Related Experiment Video
Updated: Jul 1, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Feasibility of Weight-based Tube Voltage and Iodine Delivery Rate for Coronary Artery CT Angiography
Ying Wang1, Yan Zhang1, Aihui Di1
1Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191, PR China.
Purpose:
The objective of this study was to evaluate the feasibility of weight-based tube voltage and iodine delivery rate (IDR) for coronary artery CT angiography (CCTA).
Methods:
A total of 193 patients (mean age: 58 ± 12 years) with suspected coronary heart disease indicated for CCTA between May and October 2022 were prospectively enrolled. The subjects were divided into five groups according to body weight: < 60 kg, 60 – 69 kg, 70 – 79 kg, 80 – 89 kg, and ≥ 90 kg. The tube voltage and IDR settings of each group were as follows: 70 kVp/0.8 gI/s, 80 kVp/1.0 gI/s, 80 kVp/1.1 gI/s, 100 kVp/1.5 gI/s, and 100 kVp/1.5 gI/s, respectively. Objective image quality data included the CT value and standard deviation (noise) of the aortic root (AR), the proximal left anterior descending branch (LAD), and the distal right coronary artery (RCA), as well as the signal-to-noise ratio and contrast-to-noise ratio of the LAD and RCA. Subjective image quality assessment was performed based on the 18-segment model. Contrast and radiation doses, as well as effective dose (ED), were recorded. All continuous variables were compared using either the one-way ANOVA or the Kruskal-Wallis rank sum test.
Results:
No significant differences were observed in all objective and subjective parameters of image quality between the groups (P > 0.05). However, significant differences in contrast and radiation doses were observed (P < 0.05). The contrast doses across the weight groups were 27 mL, 35 mL, 38 mL, 53 mL, and 53 mL, respectively, while the ED were 1.567 (1.30, 2.197) mSv, 1.53 (1.373, 1.78) mSv, 2.113 (1.963, 2.256) mSv, 4.22 (3.771, 4.483) mSv, and 4.786 (4.339, 5.536) mSv, respectively.
Conclusion:
Weight-based tube voltage and IDR yielded consistently high image quality, and allowed for further reduction in contrast and radiation exposure during CCTA for coronary artery diseases.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...