Clinical Implementation of Automated Oxygen Titration in a Tertiary Care Hospital
Pierre-Alexandre Bouchard1, Geneviève Parent-Racine1, Cassiopée Paradis-Gagnon1
1Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval, Québec, Québec, Canada.
Background:
When treating acute respiratory failure, both hypoxemia and hyperoxemia should be avoided. SpO2 should be monitored closely and O2 flows adjusted accordingly. Achieving this goal might be easier with automated O2 titration compared with manual titration of fixed-flow O2. We evaluated the feasibility of using an automated O2 titration device in subjects treated for acute hypoxemic respiratory failure in a tertiary care hospital.
Methods:
Health-care workers received education and training about oxygen therapy, and were familiarized with an automated O2 titration device (FreeO2,). A coordinator was available from 8:00 am to 5:00 pm during weekdays to provide technical assistance. The ability of the device to maintain SpO2 within the prescribed therapeutic window was recorded. Basic clinical information was recorded.
Results:
Subjects were enrolled from November 2020 to August 2022. We trained 508 health-care workers on the use of automated O2 titration, which was finally used on 872 occasions in 763 subjects, distributed on the respiratory, COVID-19, and thoracic surgery wards, and in the emergency department. Clinical information could be retrieved for 609 subjects (80%) who were on the system for a median (interquartile range) of 3 (2-6) d, which represented 2,567 subject-days of clinical experience with the device. In the 82 subjects (14%) for whom this information was available, the system maintained SpO2 within the prescribed targets 89% of the time. Ninety-six subjects experienced clinical deterioration as defined by the need to be transferred to the ICU and/or requirement of high flow nasal oxygen but none of these events were judged to be related to the O2 device.
Conclusions:
Automated O2 titration could be successfully implemented in hospitalized subjects with hypoxemic respiratory failure from various causes. This experience should foster further improvement of the device and recommendations for an optimized utilization.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...