Related Experiment Video
Updated: May 29, 2026

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Determination of meropenem in capillary plasma microsamples using LC-MS/MS
Maria Amélia de Castilhos Busato1,2, Amanda Pacheco Bondan1, Marcos Frank Bastiani1,2
1Laboratório de Toxicologia Analítica, Universidade Feevale, Rua Rubem Berta 200, Novo Hamburgo, Rio Grande do Sul, Brazil.
Abstract:
Background: The measurement of meropenem plasma concentrations is employed for dosing regimen individualization. The aim of this study was to develop and validate a LC-MS/MS assay for quantification of meropenem in capillary plasma microsamples. Methods: Samples were prepared by protein precipitation with acetonitrile, followed by clean-up with dichloromethane. The method was validated and applied to 12 paired samples of venous and capillary plasma. Results: The method was linear in the range of 0.5-50 μg/ml. Matrix effects were minimal. Inter- and intra-assay were 3.8-7.9% and 2.7-5.5%, respectively, while accuracy was 91.7-100.6%. Concentrations in capillary and venous plasma were highly correlated. Conclusion: An assay for the quantification of meropenem in capillary plasma microsamples was fully validated, showing potential for clinical application.