Related Experiment Video
Updated: Jun 29, 2025

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Personalized AI-Driven Real-Time Models to Predict Stress-Induced Blood Pressure Spikes Using Wearable Devices:
Ali Kargarandehkordi1, Christopher Slade1, Peter Washington1
1Department of Information and Computer Sciences, University of Hawaii at Manoa, Honolulu, HI, United States.
Background:
Referred to as the "silent killer," elevated blood pressure (BP) often goes unnoticed due to the absence of apparent symptoms, resulting in cumulative harm over time. Chronic stress has been consistently linked to increased BP. Prior studies have found that elevated BP often arises due to a stressful lifestyle, although the effect of exact stressors varies drastically between individuals. The heterogeneous nature of both the stress and BP response to a multitude of lifestyle decisions can make it difficult if not impossible to pinpoint the most deleterious behaviors using the traditional mechanism of clinical interviews.
Objective:
The aim of this study is to leverage machine learning (ML) algorithms for real-time predictions of stress-induced BP spikes using consumer wearable devices such as Fitbit, providing actionable insights to both patients and clinicians to improve diagnostics and enable proactive health monitoring. This study also seeks to address the significant challenges in identifying specific deleterious behaviors associated with stress-induced hypertension through the development of personalized artificial intelligence models for individual patients, departing from the conventional approach of using generalized models.
Methods:
The study proposes the development of ML algorithms to analyze biosignals obtained from these wearable devices, aiming to make real-time predictions about BP spikes. Given the longitudinal nature of the data set comprising time-series data from wearables (eg, Fitbit) and corresponding time-stamped labels representing stress levels from Ecological Momentary Assessment reports, the adoption of self-supervised learning for pretraining the network and using transformer models for fine-tuning the model on a personalized prediction task is proposed. Transformer models, with their self-attention mechanisms, dynamically weigh the importance of different time steps, enabling the model to focus on relevant temporal features and dependencies, facilitating accurate prediction.
Results:
Supported as a pilot project from the Robert C Perry Fund of the Hawaii Community Foundation, the study team has developed the core study app, CardioMate. CardioMate not only reminds participants to initiate BP readings using an Omron HeartGuide wearable monitor but also prompts them multiple times a day to report stress levels. Additionally, it collects other useful information including medications, environmental conditions, and daily interactions. Through the app's messaging system, efficient contact and interaction between users and study admins ensure smooth progress.
Conclusions:
Personalized ML when applied to biosignals offers the potential for real-time digital health interventions for chronic stress and its symptoms. The project's clinical use for Hawaiians with stress-induced high BP combined with its methodological innovation of personalized artificial intelligence models highlights its significance in advancing health care interventions. Through iterative refinement and optimization, the aim is to develop a personalized deep-learning framework capable of accurately predicting stress-induced BP spikes, thereby promoting individual well-being and health outcomes.
International Registered Report Identifier (Irrid):
DERR1-10.2196/55615.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure

