Related Experiment Video
Updated: Jun 29, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Computer-aided quality assessment of endoscopist competence during colonoscopy: a systematic review
Kristoffer Mazanti Cold1, Anishan Vamadevan2, Andreas Slot Vilmann3
1Copenhagen Academy for Medical Education and Simulation (CAMES), Center for HR & Education, the Capital Region of Denmark, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
Background And Aims:
Endoscopists' competence can vary widely, as shown in the variation in the adenoma detection rate (ADR). Computer-aided quality assessment (CAQ) can automatically assess performance during individual procedures. In this review we identified and described different CAQ systems for colonoscopy.
Methods:
A systematic review of the literature was done using MEDLINE, EMBASE, and Scopus based on 3 blocks of terms according to the inclusion criteria: colonoscopy, competence assessment, and automatic evaluation. Articles were systematically reviewed by 2 reviewers, first by abstract and then in full text. The methodological quality was assessed using the Medical Education Research Study Quality Instrument (MERSQI).
Results:
Of 12,575 identified studies, 6831 remained after removal of duplicates and 6806 did not pass the eligibility criteria and were excluded, leaving 25 studies, of which 13 studies were included in the final analysis. Five categories of CAQ systems were identified: withdrawal speedometer (7 studies), endoscope movement analysis (3 studies), effective withdrawal time (1 study), fold examination quality (1 study), and visual gaze pattern (1 study). The withdrawal speedometer was the only CAQ system that tested its feedback by examining changes in ADR. Three studies observed an improvement in ADR, and 2 studies did not. The methodological quality of the studies was high (mean MERSQI, 15.2 points; maximum, 18 points).
Conclusions:
Thirteen studies developed or tested CAQ systems, most frequently by correlating it to the ADR. Only 5 studies tested feedback by implementing the CAQ system. A meta-analysis was impossible because of the heterogeneous study designs, and more studies are warranted.
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...