Open-Ended Coaxial Probe for Effective Reconstruction of Biopsy-Excised Tissues' Dielectric Properties
Eliana Canicattì1, Nunzia Fontana2, Sami Barmada2
1FreeSpace Electromagnetic Technologies, 56121 Pisa, Italy.
Abstract:
Dielectric characterization is extremely promising in medical contexts because it offers insights into the electromagnetic properties of biological tissues for the diagnosis of tumor diseases. This study introduces a promising approach to improve accuracy in the dielectric characterization of millimeter-sized biopsies based on the use of a customized electromagnetic characterization system by adopting a coated open-ended coaxial probe. Our approach aims to accelerate biopsy analysis without sample manipulation. Through comprehensive numerical simulations and experiments, we evaluated the effectiveness of a metal-coating system in comparison to a dielectric coating with the aim for replicating a real scenario: the use of a needle biopsy core with the tissue inside. The numerical analyses highlighted a substantial improvement in the reconstruction of the dielectric properties, particularly in managing the electric field distribution and mitigating fringing field effects. Experimental validation using bovine liver samples revealed highly accurate measurements, particularly in the real part of the permittivity, showing errors lower than 1% compared to the existing literature data. These results represent a significant advancement for the dielectric characterization of biopsy specimens in a rapid, precise, and non-invasive manner. This study underscores the robustness and reliability of our innovative approach, demonstrating the convergence of numerical analyses and empirical validation.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Induced Electric Dipoles
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)