Related Experiment Video
Updated: Jun 27, 2025

In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
A New Planar Potentiometric Sensor for In Situ Measurements
Nikola Lenar1, Robert Piech1, Beata Paczosa-Bator1
1Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland.
Abstract:
A new construction of a potentiometric sensor was introduced for the first time. It relies on the use of two membranes instead of one, as in the well-known coated-disc electrode. For this purpose, a new electrode body was constructed, including not one, but two glassy carbon discs covered with an ion-selective membrane. This solution allows for the sensor properties to be enhanced without using additional materials (layers or additives) on the membrane. The new construction is particularly useful for in situ measurements in environmental samples. Two ion-selective polymeric membranes were used, namely H+ and K+-selective membranes, to confirm the universality of the idea. The tests conducted included chronopotentiometric tests, electrochemical impedance spectroscopy, and potentiometric measurements. The electrical and analytical parameters of the sensors were evaluated and compared for all tested electrodes to evaluate the properties of the planar electrode versus previously known constructions. Research has shown that the application of two membranes instead of one allows for the resistance of an electrode to be lowered and for the electrical capacitance to be elevated. Improving the electrical properties of an electrode resulted in the enhancement of its analytical properties. The pH measurement range of the planar electrode is 2-11, which is much wider in contrast to that of the single-membrane electrode. The linear range of the K+-selective planar electrode is wider than that of the coated-disc electrode and equals 10-6 to 10-1 M. The response time turned out to be a few seconds shorter, and the potential drift was smaller due to the application of an additional membrane in the electrode construction. This research creates a new opportunity to design robust potentiometric sensors, as the presented construction is universal and can be used to obtain electrodes selective to various ions.
More Related Videos
05:49Mechano-Node-Pore Sensing: A Rapid, Label-Free Platform for Multi-Parameter Single-Cell Viscoelastic Measurements
Published on: December 2, 2022
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Related Concept Videos
Potentiometry: Overview
Potentiometry: Membrane Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Interfacial Electrochemical Methods: Overview