Related Experiment Video
Updated: May 11, 2026

Operation of a Benchtop Bioreactor
Published on: September 12, 2013
Coffee brewing sonoreactor for reducing the time of cold brew from several hours to minutes while maintaining sensory
Shih-Hao Chiu1, Nikunj Naliyadhara2, Martin P Bucknall3
1School of Chemical Engineering, University of New South Wales, Sydney 2052, NSW, Australia; School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney 2008, NSW, Australia.
Abstract:
This research designed and developed an ultrasonic reactor for a fast and on demand production of cold brew coffee, remarkably reducing the brewing time from 24 h to less than 3 min. The technology was engineered by utilizing resonance to induce ultrasonic waves around the walls of the brewing basket of an espresso machine. The sound transmission system comprised a transducer, a horn and a brewing basket. This arrangement transformed the coffee basket into an effective sonoreactor that injected sound waves at multiple points through its walls, thereby generating multiple regions for acoustic cavitation within the reactor. Furthermore, acoustic streaming induced greater mixing and enhanced mass transfer during brewing. The design was accomplished by modeling the transmission of sound, and acoustic cavitation. Brew characterization and chemical composition analysis was performed, considering factors such as pH, acidity, color, and the composition of caffeine, fatty acids, and volatiles. The efficiency of the extraction increased by decreasing the basket loading percentage (BLP). For instance, sonicating at 100 W doubled the extraction yield and caffeine concentration, from 15.05 % to 33.44 % at BLP = 33 %, and from 0.91 mg/mL to 1.84 mg/mL at BLP = 67 %, respectively. The total fatty acids increased from 1.16 mg/mL to 9.20 mg/mL, representing an eightfold increase, at BLP = 33 %. Finally, a sensory analysis was conducted to evaluate appearance, aroma, texture, flavor, and aftertaste, which demonstrated that coffee brewed for 1 and 3 min in the sonoreactor exhibited almost undistinguishable properties compared to a standard 24 h brewing without ultrasound.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
04:36Author Spotlight: Exploring Tea Aroma Using Solvent-Assisted Flavor Evaporation Technique
Published on: May 26, 2023
Related Concept Videos
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Effect of Temperature Change on Reaction Rate
Fast Reactions
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Setting Time of Cement
Mixing Time