Validation of a clinical assay for botulinum neurotoxins through mass spectrometric detection
Kaitlin M Hoyt1, John R Barr1, André O Hopkins2
1Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, Georgia, USA.
Abstract:
Botulism is a paralytic disease due to the inhibition of acetylcholine exocytosis at the neuromuscular junction, which can be lethal if left untreated. Botulinum neurotoxins (BoNTs) are produced by some spore-forming Clostridium bacteria. The current confirmatory assay to test for BoNTs in clinical specimens is the gold-standard mouse bioassay. However, an Endopep-MS assay method has been developed to detect BoNTs in clinical samples using benchtop mass spectrometric detection. This work demonstrates the validation of the Endopep-MS method for clinical specimens with the intent of method distribution in public health laboratories. The Endopep-MS assay was validated by assessing the sensitivity, robustness, selectivity, specificity, and reproducibility. The limit of detection was found to be equivalent to or more sensitive than the mouse bioassay. Specificity studies determined no cross-reactivity between the different serotypes and no false positives from an exclusivity panel of culture supernatants of enteric disease organisms and non-toxigenic strains of Clostridium. Inter-serotype specificity testing with 19 BoNT subtypes was 100% concordant with the expected results, accurately determining the presence of the correct serotype and the absence of incorrect serotypes. Additionally, a panel of potential interfering substances was used to test selectivity. Finally, clinical studies included clinical specimen stability and reproducibility, which was found to be 99.9% from a multicenter evaluation study. The multicenter validation study also included a clinical validation study, which yielded a 99.4% correct determination rate. Use of the Endopep-MS method will improve the capacity and response time for laboratory confirmation of botulism in public health laboratories.
Related Concept Videos
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...