Related Experiment Video
Updated: Jun 27, 2025

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
An Artificial Intelligence-Driven Approach for Automatic Evaluation of Right-to-Left Shunt Grades in
Yajiao Li1, Haipeng Chen2, Ximeng Yang3
1Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Background:
Intracardiac or pulmonary right-to-left shunt (RLS) is a common cardiac anomaly associated with an increased risk of neurological disorders, specifically cryptogenic stroke. Saline-contrasted transthoracic echocardiography (scTTE) is often used for RLS diagnosis. However, the identification of saline microbubbles in the left heart can be challenging for novice residents, potentially leading to a delay in diagnosis and treatment. In this study, we proposed an artificial intelligence (AI)-based algorithm designed to automatically detect microbubbles in scTTE images and evaluate right-to-left shunt grades. This tool aims to support residency training and decrease the workload of cardiologists.
Methods:
A dataset of 23,665 scTTE images obtained from 174 individuals was included in this study. This dataset was partitioned into a training set (n = 20,475) and an internal validation set (n = 3,190) on a patient-level basis. An additional cohort of 33 patients diagnosed with cryptogenic ischemic stroke was enrolled as an external validation set. The proposed algorithm for right-to-left shunt degree classification employed the EfficientNet-b4 model, and the model's performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity, and compared to the performance of residents.
Results:
Our AI model demonstrated robust performance with an accuracy of 0.926, sensitivity of 0.827, and specificity of 0.951 on the internal testing dataset. In the external validation set, our AI model exhibited diagnostic accuracy, sensitivity, and specificity of 0.864, 0.818, and 0.909, respectively. In comparison, residents achieved values of 0.727, 0.636, and 0.818, respectively.
Conclusion:
Our AI model provides a swift, precise, and easily deployable methodology for grading the degree of right-to-left shunt in scTTE, carrying substantial implications for routine clinical practice. Residents can benefit from our artificial intelligence-based algorithm, enhancing both the accuracy and efficiency of RLS diagnosis.
More Related Videos
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...