Bivalirudin Monitoring in Pediatric Ventricular Assist Device and Extracorporeal Membrane Oxygenation: Analysis of
Elissa R Engel1,2, Tanya Perry1,3, Mary Block4
1Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH.
Insights
The activated partial thromboplastin time (aPTT) is unreliable for monitoring bivalirudin in pediatric VAD and ECMO patients. A bivalirudin-calibrated dilute thrombin time (Bival dTT) assay offers superior reliability for anticoagulation management.
Area of Science:
- Pediatric critical care medicine
- Pharmacology and therapeutics
- Clinical laboratory science
Background:
- The activated partial thromboplastin time (aPTT) is the standard assay for monitoring bivalirudin anticoagulation in pediatric patients on mechanical circulatory support (MCS).
- However, the aPTT exhibits intrinsic variability, potentially leading to suboptimal anticoagulation and increased risks of bleeding or thrombotic complications.
- Reliable monitoring is crucial for patients on ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO).
Purpose of the Study:
- To evaluate the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for monitoring bivalirudin therapy in pediatric VAD and ECMO patients.
- To compare the performance of the Bival dTT assay with the standard aPTT assay in this population.
- To assess the correlation between different laboratory parameters and bivalirudin's anticoagulant effect.
Main Methods:
- Retrospective analysis of clinical data and residual plasma samples from pediatric patients on VAD and ECMO support.
- Assessment of two drug-calibrated experimental assays, including the Bival dTT assay, validated for clinical use.
- Statistical analysis using Pearson correlation and simple linear regression to determine R2 correlation coefficients between laboratory parameters.
Main Results:
- Analysis of 115 plasma samples from 11 VAD patients showed excellent correlation between drug-calibrated assays (R2 = 0.94) and dTT (R2 = 0.87), but poor correlation with aPTT (R2 = 0.1).
- In 105 clinically ordered results from 11 ECMO patients, the Bival dTT assay demonstrated excellent correlation with standard dTT (R2 = 0.86) but very poor correlation with aPTT (R2 = 0.004).
- The Bival dTT assay was selected for validation in VAD patients based on initial findings.
Conclusions:
- The activated partial thromboplastin time (aPTT) is an unreliable assay for monitoring bivalirudin in pediatric VAD and ECMO patients due to poor correlation with anticoagulant effect.
- A drug-calibrated Bival dTT assay offers superior reliability and standardization potential across institutions for bivalirudin monitoring.
- Further studies are required to establish appropriate therapeutic ranges and correlate Bival dTT results with clinical outcomes.
Objectives:
The activated partial thromboplastin time (aPTT) is the most frequently used monitoring assay for bivalirudin in children and young adults on mechanical circulatory support including ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO). However, intrinsic variability of the aPTT complicates management and risks bleeding or thrombotic complications. We evaluated the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for bivalirudin monitoring in this population.
Design:
Retrospective analysis of clinical data (including aPTT, dilute thrombin time [dTT]) and results of residual plasma samples from VAD patients were assessed in two drug-calibrated experimental assays. One assay (Bival dTT) was validated for clinical use in VAD patients, and subsequently used by clinicians in ECMO patients. Pearson correlation and simple linear regression were used to determine R2 correlation coefficients between the different laboratory parameters using Statistical Package for Social Sciences (Armonk, NY).
Setting:
ICUs at Cincinnati Children's Hospital Medical Center.
Subjects:
Children on VAD or ECMO support anticoagulated with bivalirudin.
Interventions:
None.
Measurements And Main Results:
One hundred fifteen plasma samples from 11 VAD patients were analyzed. Both drug-calibrated experimental assays (anti-IIa and Bival dTT) showed excellent correlation with each other ( R2 = 0.94) and with the dTT ( R2 = 0.87), but poor correlation with aPTT ( R2 = 0.1). Bival dTT was selected for validation in VAD patients. Subsequently, clinically ordered results (105) from 11 ECMO patients demonstrated excellent correlation between the Bival dTT and the standard dTT ( R2 = 0.86) but very poor correlation with aPTT ( R2 = 0.004).
Conclusions:
APTT is unreliable and correlates poorly with bivalirudin's anticoagulant effect in ECMO and VAD patients. A drug-calibrated Bival dTT offers superior reliability and opportunity to standardize results across institutions. Additional studies are needed to determine an appropriate therapeutic range and correlation with clinical outcomes.
Related Concept Videos
Pharmacokinetics in Pediatric Patients: Drug Excretion
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Continuous Renal Replacement Therapy
Acute Kidney Injury IV: Diagnostic Studies and Prevention