Related Experiment Video
Updated: Jun 26, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Evaluation of a Tube Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography Using
Chiara Gnasso1, Milan Vecsey-Nagy2, U Joseph Schoepf3
1Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, South Carolina 29425, USA; Experimental Imaging Center, IRCCS San Raffaele Scientific Institute, Via Olgettina 60, Milan, Italy.
Automated tube voltage selection (ATVS)-adapted contrast medium (CM) protocols significantly reduce CM volume in coronary CT angiography (CCTA) without compromising image quality or radiation dose. This innovation optimizes CCTA for suspected coronary artery disease (CAD).
Area of Science:
- Radiology
- Cardiovascular Imaging
- Medical Physics
Background:
- Coronary CT angiography (CCTA) is a first-line diagnostic tool for suspected coronary artery disease (CAD).
- Increasing CCTA utilization necessitates strategies to minimize radiation and contrast medium (CM) exposure.
- Optimizing CM injection protocols is crucial for balancing diagnostic efficacy and patient safety.
Purpose of the Study:
- To evaluate an automated tube voltage selection (ATVS)-adapted CM injection protocol for CCTA.
- To compare its performance against a standard triphasic protocol regarding image quality, radiation dose, and CM administration.
- To assess the feasibility of reducing CM volume while maintaining diagnostic image quality.
Main Methods:
- Prospective enrollment of 120 patients undergoing CCTA with an ATVS-adapted triphasic CM protocol (70-130 kV).
- Comparison with 120 retrospective controls using a standard triphasic CM protocol on the same CT system.
- Evaluation of radiation dose, subjective image quality, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR).
Main Results:
- Significant reduction in CM volume in the ATVS group (46.0 mL) compared to the control group (51.3 mL) (p < 0.001).
- No significant differences in radiation dose (6.13 mSv vs. 5.97 mSv, p = 0.81).
- Comparable subjective image quality (median score 4 vs. 4, p = 0.40) and objective image quality (CNR, SNR) between groups.
Conclusions:
- The ATVS-adapted CM injection protocol enables diagnostic quality CCTA with reduced CM volume.
- This protocol maintains comparable radiation exposure and image quality to standard protocols.
- ATVS-adapted protocols represent a valuable advancement in optimizing CCTA procedures.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...