Background:
As volume of total hip arthroplasty (THA) continues to increase, the utilization and availability of in-traoperative advanced technologies to arthroplasty surgeons continues to rise as well. Our primary goal was to determine whether the use of a mini navigation technology extended operative times and secondarily if it affected postoperative outcomes following elective THA.
Methods:
A single-institution total joint arthroplasty da-tabase was utilized to identify adult patients who underwent elective THA from 2017 to 2019. Baseline demographic data along with surgical operative time, length of stay (LOS) and discharge disposition were collected. The Activity Measure for Post-Acute Care (AM-PAC) was used to determine physi-cal therapy progress.
Results:
A total of 1,162 THAs were performed of which 69.1% (803) used navigation while 30.9% (359) did not. Baseline demographics including age, sex, body mass index (BMI), insurance, and smoking status were not statistically different between groups. The operative time was shorter in the navigation group compared to THA without navigation (115.1 vs. 118.9 min, p < 0.0001). Mean LOS was signifi-cantly shorter in the navigation THA group as compared to THA without navigation (2.1 vs. 2.6 days, p < 0.0001). Postoperative AM-PAC scores were higher in the navigation group on postoperative day 1 as compared to patients with-out navigation (18.87 vs. 17.52, p < 0.0001). Additionally, a greater percentage of patients were discharged directly home after THA with navigation as compared to THA without navigation (89.54% vs. 83.57%, p < 0.0001).
Conclusion:
Our study demonstrates that hip navigation technology in the setting of THA is associated with reduced operative times and higher AM-PAC mobilization scores. Hip mini navigation technology shortens operative times while improving early patient outcome scores in association with shorter LOS and greater home-based discharge.