A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
[Treatment of Tile type C pelvic ring fracture using orthopedic robot combined with Starr pelvis reduction frame]
Gang-Qiang Jiang1, Fu-de Jiao1, Ji-Chong Ying1
1Department Orthopaedics, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
Objective:
To investigate the clinical effect of orthopedic robot combined with Starr pelvic reduction frame in the treatment of Tile type C pelvic ring fracture.
Methods:
From October 2019 to May 2021, 14 patients with type C pelvic ring fracture were treated with robotic combined with Starr pelvic reduction frame, including 9 males and 5 females. The age ranged from 33 to 69 years. All the 14 patients had fresh closed fractures without femur, tibia and fibula fracture. Surgery was completed from 4 to 7 d after hospital admission. During the operation, the X-ray carbon bed was used, the pelvic ring was reduced by Starr pelvis reduction frame, and pelvic ring fracture was treated by orthopedic robot. Operation time, bleeding volume, fluoroscopy times of single screw placement, fracture reduction quality, affected limb function and complications were observed. Radiological reduction was evaluated using Matta scoring standard, and clinical efficacy was evaluated by Majeed pelvic function scoring system at the final follow-up.
Results:
All of 14 patients successfully completed the operation, the operation time was 84 to 141 min, the bleeding volume was 20 to 50 ml, and the fluoroscopy times of single screw insertion was 4 to 9 times. All of 14 patients were followed up for 12 to 24 months. The healing time was 3 to 7 months. No complications such as fracture of internal fixation, screw loosening, infection and nerve injury were found. According to the evaluation criteria of Matta imaging reduction, 9 cases were excellent, 4 cases were good, and 1 case was fair. At the final follow-up, Majeed pelvic function scoring system was used:10 cases were excellent, 4 cases were good.
Conclusion:
The treatment of type C pelvic ring fracture with robotic combined Starr pelvis reduction frame is simple, time-saving, less trauma, less complications and effective.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...