Related Experiment Video
Updated: Jul 19, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Influence of Ti-Base-Supported Implant Restoration on Peri- implant Conditions: A Systematic Review and Meta-analysis
Purpose:
To conduct a systematic review and meta-analysis to examine the impact of titanium (Ti) base-supported single-implant restorations on peri-implant conditions.
Materials And Methods:
Six randomized controlled trials (RCTs) comprising 274 implants met the inclusion criteria and were chosen for data analysis. A random-effects model was employed for the meta-analysis.
Results:
Data from this study revealed that the Ti-basegroup exhibited a small but statistically significant increase in peri-implant marginal bone loss (MBL; mean difference = 0.088 mm; 95% CI = 0.003 to 0.17; P = .041) compared to the one-piece abutment group. These effects were consistent in the subgroup analysis of regularly threaded implants compared to the microthreaded subgroup. No significant differences were observed between the Ti-base group and the abutment group concerning probing depth (PD), bleeding on probing (BoP), and the risk of prosthetic-related complications.
Conclusions:
The use of a Ti-base in a single implant-supported restorationis associated with a slight increase in peri-implant MBL, while other peri-implant health parameters show no significant correlation. Therefore, the evidence of the impact that Ti-bases have on the peri-implant conditions of single implant-supported restorations is insufficient based on the findings of the present meta-analysis.